Table 337: Loss of Signal Alarm Inquiry Test (#138) 6 of 7<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Loss of Signal Alarm Inquiry Test (#138)<br />

1313 FAIL The DS1/UDS1 circuit pack could not deactivate a CPE Loopback Jack<br />

loopback.<br />

1. Enter <strong>test</strong> ds1-loop location end-loopback/span-<strong>test</strong><br />

2. If the attempt to deactivate the CPE Loopback Jack is not<br />

successful, check the cabling <strong>and</strong> investigate the problem at the<br />

CPE Loopback Jack.<br />

3. Run the <strong>test</strong> again.<br />

1314 FAIL The DS1/UDS1 circuit pack could not deactivate a far-end CSU loopback.<br />

1. Enter <strong>test</strong> ds1-loop location end-loopback/span-<strong>test</strong><br />

1320 FAIL Either a CSU module/Sync Splitter hardware failure or an ICSU/Sync<br />

Splitter serial-interface audit failure was detected by the DS1/UDS1 circuit<br />

pack.<br />

1. Replace the CSU module/Sync Splitter, <strong>and</strong> then run the <strong>test</strong> again.<br />

2. If the <strong>test</strong> continues to fail with this Error Code, replace the DS1/<br />

UDS1 circuit pack, <strong>and</strong> run the <strong>test</strong> again.<br />

3. If the <strong>test</strong> continues to fail with this Error Code, then the problem<br />

could be in the I/O cable between the backplane <strong>and</strong> the CSU<br />

module/Sync Splitter.<br />

1321 FAIL DTE LOS (loss of signal) was detected between the DS1/UDS1 board<br />

<strong>and</strong> the CSU module or the Sync Splitter. Either the DS1/UDS1 board, the<br />

CSU module/Sync Splitter, or the I/O cable between the backplane <strong>and</strong><br />

the CSU module/Sync Splitter (or any combination thereof) has failed.<br />

Attempt to isolate the problem to one of these areas.<br />

1. Replace the CSU module/Sync Splitter, <strong>and</strong> run the <strong>test</strong> again.<br />

2. If the <strong>test</strong> continues to fail with this Error Code, then replace the<br />

DS1/UDS1 board, <strong>and</strong> run the <strong>test</strong> again.<br />

3. If the <strong>test</strong> continues to fail with this Error Code, the problem could be<br />

in the I/O cable between the backplane <strong>and</strong> the CSU module/Sync<br />

Splitter.<br />