Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Cabinet Temperature Query Test (#122)<br />

This <strong>test</strong> queries for the status of the temperature <strong>and</strong> fan sensors in the cabinet. This <strong>test</strong> is run<br />

on the following maintenance objects:<br />

● AC-POWER<br />

● CABINET (Cabinet Sensors)<br />

● CARR-POW (Carrier Power Supply)<br />

● EMG-XFER (Emergency Transfer)<br />

● POWER<br />

Table 330: Cabinet Temperature Query Test (#122) 1 of 6<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1000 ABORT System resources required to run <strong>test</strong> are not available.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2000 ABORT Response from the <strong>test</strong> was not received within the time allowed.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2. S8700-series: If the <strong>test</strong> continues to abort with Error Code 2000,<br />

check for power problems with the PN’s A carrier.<br />

2029<br />

2319<br />

2500<br />

S8700-series Fiber-PNC: Look for <strong>and</strong> resolve every AC-POWER <strong>and</strong><br />

CARR-POW (Carrier Power Supply) alarm in a multicarrier cabinet<br />

or DC-POWER (Single-Carrier Cabinet Environment) alarm in a<br />

single-carrier cabinet. Repeat the <strong>test</strong>. If the <strong>test</strong> continues to abort<br />

with <strong>error</strong> code 2000, check for <strong>and</strong> resolve every MAINT (PN<br />

Maintenance Circuit Pack) <strong>error</strong> in a PN. Repeat the <strong>test</strong>.<br />

S8700-series IP-PNC:Look for <strong>and</strong> resolve every RMC-ENV (Power/<br />

Fan Sensors) alarm. Repeat the <strong>test</strong>.<br />

ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1216 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />