SER-BUS (Serial Communication Bus)<br />

certain carriers are disconnected from the Serial Bus. This is done by moving the TDM/LAN Bus<br />

terminators (AHF110) on the carrier backplane. To terminate a Serial Bus at the end of a<br />

particular carrier, the Serial Bus cable that connects the carrier to the next carrier should be<br />

unplugged <strong>and</strong> replaced with the TDM/LAN Bus terminator. When the length of the Serial Bus is<br />

modified the A carrier TN2312BP IPSI circuit pack that is essential to the Serial Bus operation<br />

<strong>and</strong> Serial Bus maintenance must still be connected to the new shortened Serial Bus.<br />

After cabling changes are made <strong>and</strong> verified, power must be restored to the port network.<br />

Circuit packs in carriers that are not part of the shortened bus are not inserted. As a result,<br />

these circuit packs are alarmed. Ignore these alarms for now. All alarms should be resolved<br />

when the cabinet is restored to its original configuration.<br />

Procedure 2 is organized into two parts:<br />

● Part 1 attempts to clear the Serial Bus fault by replacing all the bus cabling <strong>and</strong> terminators<br />

within a port-network.<br />

● Part 2 attempts to isolate the fault to a particular carrier by extending the Serial Bus from<br />

the A carrier to additional carriers one at a time.<br />

Refer to the repair procedure steps given for the Serial Bus Status Test (#1531)<br />

Error log entries <strong>and</strong> recommended actions<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

Notes:<br />

a. Error type 257: serial bus failure. There are no power supplies detected on the serial bus.<br />

<strong>Dem<strong>and</strong></strong> <strong>test</strong> <strong>descriptions</strong> <strong>and</strong> <strong>error</strong> <strong>codes</strong><br />

On/Off<br />

Board<br />

Recommended Action<br />

257 (a) Serial Bus Status Test (#1531) MIN Off <strong>test</strong> environment location<br />

Order of investigation Short <strong>test</strong><br />

sequence<br />

Long <strong>test</strong><br />

sequence<br />

Serial Bus Status Test (#1531) X X ND<br />

1. D = Destructive, ND = Nondestructive<br />

D/ND 1<br />

Issue 5 May 2009 827