Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 548: Ring Generator Interchange Test (#1539) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

2500 ABORT An internal operation failed.<br />

1. Repeat the comm<strong>and</strong> at one-minute intervals 1 to 3 times.<br />

2. If the <strong>test</strong> continues to abort escalate the problem.<br />

1 FAIL There is no ringing voltage on the backplane when interchanging the ring<br />

generator to this power supply.<br />

1. Run <strong>test</strong> board.<br />

64 FAIL Unable to interchange the ringers. The power supply being <strong>test</strong>ed has its<br />

ringer turned off.<br />

65 FAIL Unable to interchange the ringers. The power supply not being <strong>test</strong>ed has<br />

its ringer turned off.<br />

PASS The ring generation on redundant power supplies successfully<br />

interchanged.<br />

NO<br />

BOARD<br />

Description <strong>and</strong> recommendation<br />

Power supply is administered but not detected.<br />

1. Verify that the power supply is plugged in.<br />

2. If the power supply was already plugged in, replace the power<br />

supply.<br />

Ring Generator Status Test (#1540)<br />

The ring generator status <strong>test</strong> verifies that the power supply ring voltage detector detects the<br />

presence of ringing voltage. The operational status information from the ring generator does not<br />

indicate that the generator is:<br />

● shut down because it has an internal fault or shorted lead<br />

● active but its output is operating under overload<br />

This <strong>test</strong> does not fail if the ring selector switch on the 655A power supply is disabled.<br />

This <strong>test</strong> runs on This <strong>test</strong> runs on PS-RGEN (Power Supply Ring Generator).<br />

1706 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

2 of 2