Table 306: Analog Electronic Power Feed Test (#56)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Analog Electronic Power Feed Test (#56)<br />

ABORT The <strong>test</strong> was aborted due to an internal system <strong>error</strong> on a software<br />

request to the board.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1000 ABORT System resources required to run this <strong>test</strong> are not available. The port may<br />

be busy with a valid call.<br />

1. Enter display port location to determine the station<br />

extension of the port.<br />

2. Enter status station to determine the service state of the port. If<br />

the port is in use, wait until the port is idle before <strong>test</strong>ing.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

FAIL The <strong>test</strong> failed while was attempting to turn on the EPF. Internal <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

PASS The Analog Electronic Power Feed <strong>test</strong> passed. The message to turn on<br />

the power to the station was successfully sent to the port.<br />

1. Although this <strong>test</strong> will never actually return a FAIL result except for<br />

an internal system <strong>error</strong>, it will log an <strong>error</strong> if the overcurrent case is<br />

detected by the hardware. Check the Error Log for any entries with<br />

Error Type 257 when the <strong>test</strong> has completed.<br />

2. If Error Type 257 does not appear in the Error Log within 10 seconds<br />

after completion of this <strong>test</strong>, it is safe to assume that the <strong>test</strong> sensed<br />

no problems with the power to the station. To verify that the station is<br />

powered up correctly, run a self-<strong>test</strong> on the station, if available, <strong>and</strong><br />

check that every feature button is operating.<br />

3. The appearance of Error Type 257 in the Error Log indicates a<br />

station power problem. Check for a wiring short, a damaged jack, a<br />

defective voice terminal, or an incorrect type of terminal.<br />

0 NO<br />

BOARD<br />

See NO BOARD for the repair procedures.<br />

Issue 5 May 2009 1163