Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 426: Primary Signaling Link Hardware Check (#636) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

8 FAIL ATM-SGRP: There is a problem with the ATM TN230X circuit pack or<br />

the ATM signaling chel (D-chel), preventing any ISDN trunk calls until<br />

the problem is resolved.<br />

1. Consult the procedures for the TN230X ATM-TRK (Circuit<br />

Emulation Service Circuit Pack) <strong>and</strong> the ATM-DCH (ATM D-Chel<br />

Port).<br />

ISDN-SGR: There is a problem with the UDS1 TN464 UDS1 circuit pack<br />

or the DS1 Interface Media Module or the ISDN-PRI Signaling Chel<br />

(D-chel). No ISDN trunk or PRI endpoint calls can be made until the<br />

problem is resolved.<br />

1. Consult the procedures for the UDS1-BD (UDS1 Interface Circuit<br />

Pack) or the MG-DS1 (DS1 Interface Media Module), <strong>and</strong> the<br />

ISDN-PLK (ISDN-PRI Signaling Link Port).<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

PASS The basic physical connectivity of the primary D-Chel is intact <strong>and</strong><br />

functional. Try this <strong>test</strong> repeatedly to ensure the link is up <strong>and</strong> to uncover<br />

any transitory problems.<br />

See NO BOARD for the repair procedures.<br />

Remote Layer 3 Query (#637)<br />

This <strong>test</strong> will query the far-end switch or terminal adapter to determine whether the signaling<br />

connection is functioning properly at Layer 3. It will select a B-Chel in the in-service or<br />

maintenance service state <strong>and</strong> send an ISDN layer-3 SERVice message, which requires a<br />

response from the far end. The <strong>test</strong> will not be performed if there are no B-Chels in an<br />

appropriate ISDN service state (as when none are administered or they are all out of service).<br />

Note:<br />

Note: Enter status trunk grp#/mem# or status pri-endpoint to see the<br />

service state.<br />

A PASS indicates only that a message was successfully sent to the far-end switch or terminal<br />

adapter. The ISDN PRI Specification allows up to 2 minutes for a response.<br />

1428 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

2 of 2