Note: G700:<br />

UDS1-BD (UDS1 Interface Circuit Pack)<br />

ad. Error Type 3901: provides status information about a Far CSU Loopback <strong>test</strong>. The value in<br />

the Aux Data field indicates the status of the loopback <strong>test</strong>.<br />

Aux Data Test Status<br />

1 Test is currently running<br />

2 Failed because loopback could not be activated<br />

3 Failed because <strong>test</strong> pattern could not be detected<br />

4 Test has been terminated<br />

ae. Error Type 3902: provides status information about a One-Way Span <strong>test</strong>. The value in the<br />

Aux Data field indicates the status of the span <strong>test</strong>.<br />

Aux Data Test Status<br />

1 Test is currently running<br />

2 Failed because <strong>test</strong> could not be activated<br />

3 Test pattern was not received from the far end<br />

4 Test has been terminated<br />

Note:<br />

If the One-Way Span <strong>test</strong> is run between a circuit pack <strong>and</strong> a DS1 Interface<br />

Media Module on a G700 Media Gateway, the <strong>test</strong> will fail because the DS1<br />

Media Module does not frame-align its <strong>test</strong> pattern.<br />

af. Error Type 3999: indicates that the circuit pack sent a large number of control chel<br />

messages to the switch within a short period of time. If Error Type 1538 is also present, then<br />

the circuit pack was taken out-of-service due to hyperactivity. If Error Type 1538 is absent,<br />

then the circuit pack was not taken out-of-service, but it has generated 50% of the<br />

messages necessary to be considered hyperactive. This might be completely normal during<br />

heavy traffic periods. However, if this Error Type is logged when the circuit pack is being<br />

lightly used, it might indicate a problem with the circuit pack or the equipment attached to it.<br />