CLAN-BD (Control LAN Circuit Pack)<br />

MO Name in Log Alarm<br />

Level<br />

Control LAN circuit pack<br />

The TN799 Control LAN (C-LAN) circuit pack provides TCP/IP connection to adjunct<br />

applications such as CMS, INTUITY, <strong>and</strong> DCS Networking. The C-LAN circuit pack has one<br />

100BASE-T Ethernet connection <strong>and</strong> up to 16 DS0 physical interfaces for PPP connections.<br />

C-LAN also extends ISDN capabilities to csi models by providing packet bus access. The<br />

TN799DP also supports QoS.<br />

A RSCL (remote socket control link) links the C-LAN <strong>and</strong> the server to pass call control <strong>and</strong><br />

other management information. Because one link serves every port on the circuit pack,<br />

maintenance of the RSCL is part of the C-LAN circuit-pack maintenance.<br />

C-LAN socket load balancing<br />

The C-LAN socket load balancing feature provides for a more uniform balancing of the load<br />

across the available C-LANs. With this feature, an IP endpoint registers to the C-LAN with the<br />

least number of used sockets (regardless of the number of available sockets). This applies to<br />

the following IP endpoints:<br />

● H.245, H.248, <strong>and</strong> H.323 signaling groups<br />

● H.323 stations<br />

Initial Comm<strong>and</strong> to Run Full Name of MO<br />

CLAN-BD MIN <strong>test</strong> board location long Control LAN circuit pack<br />

WRN <strong>test</strong> board location<br />

● SIP endpoints<br />

Socket counts include H.245 <strong>and</strong> H.248 endpoints but the load-balancing algorithm will not be<br />

used for registering these endpoints. Sockets used by adjuncts are not included in the socket<br />

count.<br />

Note:<br />

Note: This allocation is performed for the C-LANs assigned within each network region,<br />

independently of the C-LANs assigned to other network regions.<br />

The system logs a warning to the <strong>error</strong> log when a TN799x circuit pack has reached the socket<br />

usage value specified in the Number of CLAN Sockets Before Warning field on the<br />

ip-interfaces form. The warning can be viewed using display <strong>error</strong>s.<br />

264 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers