Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 425: BRI Set Audits Test (#630) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1187 ABORT The circuit pack, port or station may have been busied out by a technician.<br />

1. Look in the Error Log for Error Type 18 (busied out) for BRI-BD,<br />

BRI-PORT, or BRI-SET.<br />

a. If this Error Type is present for BRI-SET only, release the station<br />

with release station.<br />

b. If this Error Type is present for BRI-PORT <strong>and</strong> BRI-SET, release<br />

the port with release port location <strong>and</strong> run the <strong>test</strong> again.<br />

c. If the <strong>error</strong> is present for BRI-BD, BRI-PORT, <strong>and</strong> BRI-SET, enter<br />

release port location to release the circuit pack, <strong>and</strong> run<br />

the <strong>test</strong> again.<br />

d. If the <strong>error</strong> is present for both BRI-BD <strong>and</strong> BRI-PORT, enter<br />

release board location to release the circuit pack, <strong>and</strong> run<br />

the <strong>test</strong> again.<br />

Note: When<br />

Note:<br />

you release the circuit pack, you release every port<br />

associated with it. Enter busyout port location if<br />

ports still need to be busied out.<br />

2. Make sure the terminal is connected.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

4. If the <strong>test</strong> continues to abort, escalate the problem.<br />

2012 ABORT Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2100 ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2. If the <strong>test</strong> continues to abort, escalate the problem.<br />

PASS The switch has successfully executed the BRI station audit <strong>test</strong>.<br />