ESS (Enterprise Survivable Server)<br />

ESS (Enterprise Survivable Server)<br />

MO Name in Log Alarm Level Initial Comm<strong>and</strong> to Run Full Name of MO<br />

ESS MAJ<br />

MIN<br />

The Enterprise Survivable Server (ESS) maintenance object (MO) monitors the status of the<br />

ESS feature.<br />

On the Main server, the MO will:<br />

● Monitor the registration status for all administered ESS servers. The comm<strong>and</strong>s display<br />

survivable-processor <strong>and</strong> display system-parameters port-networks list<br />

the administered ESS servers. The registration status of all ESS servers is initially<br />

checked approximately ten minutes after the Main boots up. Subsequent to this, the<br />

registration status for all ESS servers is monitored each time an ESS server registration<br />

status change is received at the Main server.<br />

On an ESS server, the MO will:<br />

● Monitor the registration status of the active server within an ESS. Only the active server of<br />

an ESS server pair will register with the active Main server. The ESS MO at an ESS server<br />

does not track the registration status of other ESS servers.<br />

● Monitor the IP Server Interface (IPSI) socket connections for all administered IPSI circuit<br />

packs. Each ESS server establishes a socket connection to all administered IPSI circuit<br />

packs. These connections advertise the ESS server administered values to all IPSIs. If<br />

needed, the IPSI will use this socket connection to request service from the ESS.<br />

Error log entries <strong>and</strong> recommended actions<br />

Table 104: ESS Error Log Entries 1 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

None Enterprise Survivable Server<br />

On/Off<br />

Board<br />

Recommended Action<br />

1 (a) None MAJ OFF ESS controlling Port Network(s).<br />

Resolve any server <strong>and</strong>/or network<br />

problems. Schedule or initiate an<br />

on-dem<strong>and</strong> switchback of Port<br />

Networks to the Main server.<br />

257 (b) None MIN OFF ESS is not registered. Resolve any<br />

server <strong>and</strong>/or network problems.<br />

1 of 2<br />