Notes:<br />

a. Error Type 0: run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each appropriate <strong>test</strong>’s description, <strong>and</strong> follow its recommended<br />

procedures.<br />

b. Error Type 1: this <strong>error</strong> indicates the circuit pack totally stopped functioning or it was<br />

physically removed from the system.<br />

Note: The<br />

Note:<br />

alarm is logged approximately 11 minutes after the circuit pack is removed/<br />

SAKI Sanity <strong>test</strong> (#53) fails.<br />

If the circuit pack is not present in the system, insert a circuit pack in the slot indicated by<br />

the <strong>error</strong> to resolve the <strong>error</strong>.<br />

If the circuit pack is present in the system, it is faulty <strong>and</strong> must be replaced. See Replacing<br />

the IPSI or Tone-Clock Circuit Pack.<br />

If the faulty circuit pack is in st<strong>and</strong>by mode, a MINOR alarm is raised, but no other system<br />

action is taken. If the circuit pack is the active Tone-Clock, further effects of this <strong>error</strong><br />

depend on the system’s reliability option.<br />

Table 269: Effects of Tone-Clock Failures Depending on Reliability MTAR<br />

Reliability Option Effects<br />

St<strong>and</strong>ard EPN goes down<br />

Duplex PN goes down.<br />

High IPSI interchange in IPSI connected PN<br />

non IPSI connected PN goes down<br />

Critical IPSI interchange in IPSI connected PN<br />

Interchange to st<strong>and</strong>by Tone-Clock circuit pack in non IPSI<br />

connected PN<br />

If an interchange is attempted in an MCC PN <strong>and</strong> the system is unable to activate the<br />

st<strong>and</strong>by Tone-Clock, Emergency Transfer is activated. When this happens, both circuit<br />

packs are faulty <strong>and</strong> must be replaced. See Replacing the IPSI or Tone-Clock Circuit Pack.<br />

If a successful interchange occurs in response to a failure of the active Tone-Clock or if a<br />

st<strong>and</strong>by Tone-Clock fails, the faulty Tone-Clock should be replaced.<br />

c. Error Type 18: the indicated IPSI or Tone-Clock circuit pack has been made unavailable by<br />

busyout tone-clock location or busyout ipserver-interface location.<br />

This <strong>error</strong> applies only to high- or critical-reliability systems (an active Tone-Clock may not<br />

be busied out). To resolve this <strong>error</strong>, enter release tone-clock location, or<br />

release ipserver-interface location.<br />