Communication Manager Maintenance Object Repair Procedures<br />

ASAI-RES (TN800 reserve slot)<br />

MO Name in Log Alarm<br />

Level<br />

Initial Comm<strong>and</strong> to Run Full Name of MO<br />

ASAI-RES NONE NONE TN800 ASAI reserve slot<br />

DIG-RES NONE NONE TN800 DIG reserve slot<br />

Error log entries <strong>and</strong> <strong>test</strong>s also apply to DIG-RES (TN800 reserve slot).<br />

There are no <strong>test</strong>s associated with these MOs. Both the <strong>test</strong> board <strong>and</strong> busyout board<br />

comm<strong>and</strong>s abort when either is attempted on a reserved slot. An <strong>error</strong> message indicates the<br />

slot is associated with the circuit pack that the TN800 is emulating, but the requested operation<br />

is not valid.<br />

The TN800 MAPD (Multi-Application Platform) circuit pack connects to the switch through a<br />

single slot in the backplane. The number of slots occupied by the MAPD pack is supplied by the<br />

board when inserted. The TN800 in R5EM is three slots wide. The TN800 requires 2 reserve<br />

slots to its left. The reserve (blank) slots are to left of the functional slot <strong>and</strong> are place holders on<br />

the switch, <strong>and</strong> do not have any interaction with the switch.<br />

Each instance of these MOs represents a reserve slot associated with respective circuit pack<br />

mode in which the MAPD is working.<br />

114 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers