Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 391: DS1 OPS Switchhook Inquiry Test (#312) 2 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1004 ABORT The port has been seized by a user for a valid call.<br />

1. Enter status station to determine when the port is available<br />

for <strong>test</strong>ing.<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1005 ABORT Incompatible configuration administered in station administration.<br />

1. Enter display station to verify that the station is not the 24th<br />

port of the DS1 Interface circuit pack while common chel signaling<br />

is specified.<br />

2. Enter display ds1 to check the signaling type of the DS1 circuit<br />

pack.<br />

1006 ABORT The station is out of service. This condition may be accompanied by an<br />

Error Type 18 entry in the <strong>error</strong> log. Determine why the station was<br />

taken out of service. When stations are taken out of service by<br />

maintenance software, the problems that led up to that must be<br />

cleared.<br />

1. Enter status station to check the state of the port. If the port<br />

is indeed out of service, enter release station to bring the<br />

station back into service.<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1020 ABORT The DS1 Interface circuit pack is out-of-service.<br />

1. Look for DS1-BD/UDS1-BD <strong>error</strong>s in the Error Log. If present, see<br />

DS1-BD (DS1 Interface Circuit Pack).<br />

2. Retry the comm<strong>and</strong>.<br />

2000 ABORT The response to the <strong>test</strong> was not received within the allowed time.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2. If the <strong>test</strong> aborts with Error Code 2000 again, run short <strong>test</strong><br />

sequence on the associated DS1-BD or UDS1-BD. If <strong>test</strong>s 138<br />

through 145 on the associated DS1-BD or UDS1-BD are also<br />

aborting with Error Code 2000, hyperactivity on the board or<br />

facility is indicated. In this case, the hyperactivity problem should<br />

be dealt with first. See Hyperactive DS1/UDS1 Interface Circuit<br />

Pack/Media Module for the recommended procedures.<br />

1352 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />