Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 458: Packet Interface Memory Checksum Test (#884) 3 of 4<br />

Error<br />

Code<br />

1<br />

2<br />

3<br />

Test<br />

Result<br />

Description / Recommendation<br />

FAIL The Boot PROM memory checksum <strong>test</strong> failed.<br />

The Flash memory checksum <strong>test</strong> failed.<br />

Both the Boot PROM <strong>and</strong> Flash memory checksum <strong>test</strong>s failed.<br />

The circuit pack may still be operational.<br />

1. The failure may be the result of old firmware not supporting new<br />

software operation. Verify the IPSI circuit pack’s firmware vintage<br />

<strong>and</strong> download the newer firmware if appropriate.<br />

2. The firmware image on the IPSI circuit pack may have been<br />

corrupted. Download the appropriate firmware image.<br />

3. Retry the comm<strong>and</strong>. If the same Error Code occurs:<br />

a. If this is a st<strong>and</strong>ard- or duplex-reliability system, replace the<br />

circuit pack at a time that would cause the least disruption of<br />

service. The circuit pack is still functional but should be<br />

replaced since it may not operate after a system reboot <strong>and</strong> it<br />

will enter a fatal fault state if it is reset for other reasons.<br />

b. If the Packet Interface module is on the st<strong>and</strong>by IPSI, replace<br />

that circuit pack.<br />

S8700-series Fiber-PNC: If the Packet Interface module is on the<br />

st<strong>and</strong>by IPSI <strong>and</strong> this is a high- or critical-reliability system,<br />

replace that circuit pack.<br />

c. If the Packet Interface module is on the active IPSI, enter<br />

set ipserver-interface to perform a pled IPSI<br />

interchange.<br />

S8700-series Fiber-PNC: If the Packet Interface module is on the<br />

active IPSI <strong>and</strong> this is a high- or critical-reliability system, enter<br />

set ipserver-interface to perform a pled IPSI<br />

interchange.<br />

PASS The circuit pack’s firmware is in a proper state. If problems are still<br />

reported on the circuit pack, check for <strong>error</strong>s on the Packet Interface<br />

Private Looparound Test (#885) <strong>and</strong> Packet Interface Maintenance<br />

Looparound Test (#886).<br />

1526 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

3 of 4