Table 546: Power Supply Temperature Test (#1537) 2 of 2<br />

Error<br />

Code<br />

1<br />

2<br />

3<br />

Test<br />

Result<br />

Power Supply Temperature Test (#1537)<br />

FAIL The inlet temperature is over threshold.<br />

The exhaust temperature is over threshold.<br />

Both the inlet <strong>and</strong> the exhaust temperatures are over threshold.<br />

1. Enter <strong>test</strong> board location to check the temperature.<br />

2. If redundant power supplies are present, there may be a problem<br />

with the backplane. Verify that each power supply can detect the<br />

problem by using recycle carrier, specifying the slot number<br />

of the power supply to be shut down. Refer to the notes <strong>and</strong><br />

cautions for this comm<strong>and</strong> in Maintenance Comm<strong>and</strong>s for <strong>Avaya</strong><br />

Aura Communication Manager, Media Gateways <strong>and</strong> Servers<br />

(03-300431) before executing recycle carrier.<br />

3. Replace the power supply.<br />

4. If the problem persists, check the backplane for shorts.<br />

4 FAIL There is a hot spot temperature warning.<br />

8 FAIL There is a hot spot temperature shutdown.<br />

0 NO<br />

BOARD<br />

Description <strong>and</strong> recommendation<br />

PASS The inlet, exhaust, <strong>and</strong> hot spot temperatures are within limits.<br />

The power supply is administered but not detected.<br />

1. Verify that the power supply is plugged in.<br />

2. Replace the power supply.<br />

2 of 2<br />

Issue 5 May 2009 1703