Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 308: Hybrid Line Local Digital Looparound Test (#58) 2 of 2<br />

Error<br />

Code<br />

1004 ABORT The port was seized by a valid call during the <strong>test</strong>.<br />

1. Enter display port location to determine the station<br />

extension number of the port.<br />

2. Enter status station to determine the service state of the port. If<br />

the port is in use, wait until it is idle before <strong>test</strong>ing.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1<br />

2<br />

3<br />

Test<br />

Result<br />

FAIL The control chel between the processor <strong>and</strong> the port is not transmitting<br />

properly. This port is not operable.<br />

1. Retry the <strong>test</strong>.<br />

2. If the failure still occurs, enter busyout location <strong>and</strong> release<br />

location, <strong>and</strong> then re<strong>test</strong>.<br />

3. If the failure is occurring on more than one port on the board,<br />

suspect the board.<br />

4. If the failure is occurring on several boards in the same carrier,<br />

escalate the problem.<br />

5. If the failure appears to be isolated to one port, check all wiring to<br />

the set <strong>and</strong> all set connections.<br />

6. Replace the circuit pack as a last resort.<br />

PASS The control chel is transmitting properly.<br />

1. If complaints still exist, investigate by using other circuit pack <strong>test</strong>s,<br />

<strong>and</strong> by examining the station, wiring, <strong>and</strong> connections.<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

See NO BOARD for repair procedures.<br />