Digital Station Audits Test (#17)<br />

Digital Station Audits Test (#17)<br />

This <strong>test</strong> is a series of audits. This <strong>test</strong> is run on PDMODULE, TDMODULE, digital stations,<br />

softphone applications, <strong>and</strong> IP phones. This <strong>test</strong> is run on a station only if the station is<br />

in-service. The following audits are performed:<br />

● Switch hook Inquiry: This is an update of the server’s software records based on the<br />

on-hook/off-hook status of the data module or voice terminal.<br />

● Station ID Request: A request is made to the data module or station for its status. The data<br />

module or station returns its configuration <strong>and</strong> health information. This information is<br />

checked <strong>and</strong> a pass/fail result is provided.<br />

● EPF inquiry: The <strong>test</strong> requests the status of the Electronic Power Feed. EPF is not used<br />

for data modules.<br />

● Bad Scan Inquiry: An uplink message is sent containing a count generated by certain<br />

events relating to the link conditions. This can be an indication of communication problems<br />

between the server <strong>and</strong> the digital port board or media module.<br />

● Ringer Update: This updates the ringer state according to the server’s records.<br />

● DTMP Administration Update: This sends a message to the digital station to refresh the<br />

default value that causes the station to send touch-tones only in the primary information<br />

chel. This value is initially set when the station is put in-service <strong>and</strong> each time the station’s<br />

state changes from another state to in-service. This <strong>test</strong> is not used with data modules.<br />

This <strong>test</strong> runs on the following maintenance objects:<br />

● DIG-IP-S (Digital IP Station)<br />

● DIG-LINE (Digital Line)<br />

● PDMODULE (Processor Data Module)<br />

● TDMODULE (Trunk Data Module)<br />

● RC-BD (Radio Controller Board)<br />

Issue 5 May 2009 1117