Table 286: Conference Circuit Test (#7) 2 of 7<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Conference Circuit Test (#7)<br />

1000 ABORT System resources required to run this <strong>test</strong> are not available. The port<br />

may be busy with a valid call.<br />

DAT-LINE:<br />

1. :Enter status data-module to determine if the port is idle.<br />

2. If the port is idle, retry the <strong>test</strong> at 1-minute intervals up to 5 times.<br />

PE-BCHL:<br />

1. :Enter status pri-endpoint extension to determine if the<br />

port is idle.<br />

2. If the port is idle, retry the <strong>test</strong> at 1-minute intervals up to 5 times.<br />

WAE-PORT:<br />

1. :Enter status access-endpoint extension to determine if<br />

the port is idle.<br />

2. If the port is idle, retry the <strong>test</strong> at 1-minute intervals up to 5 times.<br />

CO-DS1, DID-DS1, TIE-DS1:<br />

1. Enter display port location to determine the trunk group/<br />

member number of the port.<br />

2. Enter status trunk to determine the service<br />

state of the port. If the port is in use, wait until it is idle before<br />

re<strong>test</strong>ing.<br />

3. If the port status is active but the port is idle (no calls), check the<br />

<strong>error</strong> log for Error Type 1025. See the <strong>error</strong> log table for a<br />

description of this <strong>error</strong> <strong>and</strong> required actions for this maintenance<br />

object (CO-DS1 (DS1 CO Trunk), DID-DS1 (Direct Inward Dial<br />

Trunk), TIE-DS1 (DS1 Tie Trunk)). The port may be locked up.<br />

4. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

All other Maintenance Objects:<br />

1. Enter display port location to determine the trunk group/<br />

member number or station extension of the port.<br />

2. Enter status trunk or status station<br />

extension to determine the service state of the port. If the port is<br />

in use, wait until it is idle before re<strong>test</strong>ing.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2 of 7<br />

Issue 5 May 2009 1093