Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 359: Data Module Internal Looparound Test (#175) 3 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2000 ABORT Data module is disconnected.<br />

1. Verify that the data module is powered (power LED on).<br />

2. Make sure data module is connected to the building wiring. Check<br />

for faulty wiring <strong>and</strong> faulty data module.<br />

3. Retry the comm<strong>and</strong> at one-minute intervals a maximum of 5 times.<br />

4. Replace the Data Module <strong>and</strong> repeat the <strong>test</strong>.<br />

5. If the <strong>test</strong> continues to abort, replace the Digital Line circuit pack <strong>and</strong><br />

repeat the <strong>test</strong>.<br />

2005 ABORT The h<strong>and</strong>shake between the Maintenance/Test digital port <strong>and</strong> the Data<br />

Module failed.<br />

1. Look for M/T-DIG <strong>error</strong>s in the Error Log. If present, see M/T-DIG<br />

(Maintenance/Test Digital Port).<br />

2. If <strong>test</strong> still aborts on retry, check physical connection of data module<br />

under <strong>test</strong>. Make sure the switches are on NORM, OFF (between<br />

REM_LP <strong>and</strong> LOC_LP), 9600, <strong>and</strong> ASYN.<br />

3. If the <strong>test</strong> still aborts, replace the Data Module.<br />

2012 ABORT System call failed. Internal <strong>error</strong>.<br />

1. Try the comm<strong>and</strong> again at 1-minute intervals up to 5 times.<br />

2312 ABORT The looparound <strong>test</strong> failed to receive loopback data.<br />

1. Check for M/T-DIG <strong>error</strong> in the Error Log. If present, see M/T-DIG<br />

(Maintenance/Test Digital Port).<br />

2. Retry the <strong>test</strong>. If it still aborts, replace the Data Module <strong>and</strong> re<strong>test</strong>.<br />

3. If the <strong>test</strong> aborts again, replace the Digital Line circuit pack.<br />

2313 ABORT The Maintenance/Test digital port allocated for this <strong>test</strong> did not respond to<br />

downlinked message.<br />

1. Look for M/T-DIG <strong>error</strong>s in the Error Log. If present, see M/T-DIG<br />

(Maintenance/Test Digital Port).<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

3. If the <strong>test</strong> continues to abort, replace the MTB.<br />