Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 452: DS1 Facilities Connectivity Loopback Test (#790) 3 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

55 FAIL TN1654 DS1 converter packet facility is down <strong>and</strong> can’t send loop-up<br />

message to the far end.<br />

1. Enter display <strong>error</strong>s <strong>and</strong> follow the associated repair<br />

procedures for any DS1-FAC (DS1 Facility) <strong>error</strong>s on the DS1<br />

facilities at both ends of the DS1 converter complex. If an alarm<br />

exists on a DS1 facility, then this <strong>test</strong> will fail.<br />

2. Check the DS1 connections, both circuit packs should have their<br />

DS1 facilities connected identically.<br />

3. Check the DS1 Converter Measurements Report to see if there are<br />

facilities with excessive <strong>error</strong>s. Enter list measurements<br />

ds1-facility summary. If there are facilities with excessive<br />

<strong>error</strong>s, run the Far-End Internal Loopback <strong>test</strong> (#797) via <strong>test</strong><br />

ds1-facility location long on those facilities, <strong>and</strong> follow<br />

repair procedures described for the Far-End Internal Loopback Test<br />

(#797).<br />

4. Both circuit packs may not have the same translation information.<br />

Run the DS1C Board Options Audit (#795) using <strong>test</strong> board<br />

location for both circuit packs in the DS1 converter complex to<br />

send the options. Check the results of this audit <strong>test</strong>. This <strong>test</strong> does<br />

not pass until the audit <strong>test</strong> problems are resolved.<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

PASS DS1 facility connections are correct.<br />

See NO BOARD for the repair procedures.<br />

1510 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />