Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

DS1 Interface Options Audit (#798)<br />

This <strong>test</strong> sends the administered DS1 Interface options to the DS1 converter circuit pack.<br />

Options are sent to both DS1 converter circuit packs at the same time to prevent any<br />

transitional mismatch of options.<br />

The following DS1 facility options are sent to the TN574 DS1 converter circuit pack: Framing<br />

Mode, Line Coding <strong>and</strong> DS1 converter-1 <strong>and</strong> DS1 converter-2 Line Compensation.<br />

The following DS1 facility options are sent to the TN1654 DS1 converter circuit pack: Line<br />

Coding, <strong>and</strong> DS1 converter-1 <strong>and</strong> DS1 converter-2 Line Compensation (T1 only). These option<br />

fields appear on the Fiber-link Administration screen.<br />

This <strong>test</strong> runs on the DS1-FAC (DS1 Facility) maintenance object.<br />

Table 455: DS1 Interface Options Audit (#798) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

105 ABORT The neighbor DS1 converter circuit pack at the other end of the DS1<br />

converter complex is not accessible.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2100 ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2000 ABORT Timed out while waiting for a response from the circuit pack.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2300 ABORT The downlink message necessary to run this <strong>test</strong> could not be sent.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2301 ABORT The timer could not be set before sending the downlink message<br />

necessary to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2316 ABORT Fiber link is not administered.<br />

1. Enter add fiber-link to administer the DS1 converter fiber link,<br />

then rerun the <strong>test</strong>.<br />

2500 ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

1516 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />