Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

RC Hardware Translation Audit (#1317)<br />

This <strong>test</strong>s validates that the operating parameters which are translated for an RC circuit pack<br />

match those that have been previously downloaded to the circuit pack.<br />

If this audit fails, an <strong>error</strong> will be logged <strong>and</strong> a WARNING alarm generated. However, no attempt<br />

will be made to correct the mismatched data by re-downloading to the RC. Instead, the RC<br />

circuit pack needs to be reset to have the operating parameters re-downloaded to the circuit<br />

pack. The RC circuit pack cot accept operating parameter updates <strong>and</strong> still remain in-service.<br />

This <strong>test</strong> is run on RC-BD (Radio Controller Board).<br />

Table 513: RC Hardware Translation Audit (#1317) 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2000 ABORT No response to the <strong>test</strong> from the RC circuit pack.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2. If no response, busy, reset, <strong>and</strong> release the RC board to<br />

re-initialize it. Retry the comm<strong>and</strong>.<br />

3. If the <strong>test</strong> continues to abort, escalate the problem.<br />

2012 ABORT Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2. If the <strong>test</strong> continues to abort, escalate the problem.<br />

2100 ABORT Could not allocate the necessary resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2. If the <strong>test</strong> continues to abort, escalate the problem.<br />

1 FAIL The RC has incorrect radio frequencies.<br />

1. Enter display radio-controller loc to check the<br />

administration. If administered translations are wrong, use<br />

change carrier-frequencies <strong>and</strong>/or change system<br />

parameters wireless to modify as needed.<br />

2. Re-initialize the RC board using the busy, reset, <strong>and</strong> release<br />

comm<strong>and</strong>s.<br />

1640 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />