19.12.2012 Views

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Communication Manager Maintenance Object Repair Procedures<br />

Table 55: Error type 1281 Aux Data <strong>and</strong> repair procedures 1 of 3<br />

Aux<br />

Data<br />

Alarm<br />

Description<br />

15 SYSCLOCK<br />

failed<br />

16 Loss of Signal:<br />

LOS<br />

17 Loss of Frame:<br />

LOF<br />

18 Multiplexer<br />

Section Alarm<br />

Indication<br />

Signal:<br />

MS_AIS<br />

Repair procedure<br />

The board is not locked to the TDM backplane clock signal. This is<br />

probably due to a Tone-Clock problem.<br />

1. Check for TDM-BUS or TONE-BD <strong>error</strong>s in the Error Log.<br />

2. If no other problems are present, reset the circuit pack with<br />

reset board location<br />

The fiber is not connected properly to the ATM-TRK board or ATM<br />

switch (or to the multiplexer section [MUX] if present).It is possible<br />

that the board transceivers are not functioning properly.<br />

1. Run <strong>test</strong> board location.<br />

2. If Test #1259 fails with Error Code 16, connect a fiber<br />

back-to-back in a looped mode (one str<strong>and</strong> of fiber connecting the<br />

transmit transceiver to the receive transceiver of the board) <strong>and</strong><br />

see if the amber LED flash goes away. If it does the problem is<br />

off-board.<br />

3. If the amber LED continues to flash, replace the circuit pack.<br />

The fiber signal cot obtain or maintain STM-1/OC-3 framing.<br />

1. Try to more the fiber on the ATM switch side to a different port.<br />

2. If the problem persists, reset the circuit pack with reset board<br />

location.<br />

There is a major problem on the far end (between multiplexer<br />

section [MUX] <strong>and</strong> the switch) that prohibits the circuit pack from<br />

sending a valid signal.<br />

1. See if the ports at the MUX <strong>and</strong>/or the ATM switch are connected<br />

snugly.<br />

2. Run <strong>test</strong> board location.<br />

3. If Test #1259 fails with Error Code 18, connect a fiber<br />

back-to-back in a looped mode (one str<strong>and</strong> of fiber connecting the<br />

transmit transceiver to the receive transceiver of the board) <strong>and</strong><br />

see if the amber LED flash goes away.<br />

4. If it does the problem is off-board.<br />

5. If the amber LED continues to flash, replace the circuit pack; if the<br />

<strong>error</strong> persists, escalate the problem.<br />

190 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

1 of 3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!