Table 196: M/T-DIG Error Log Entries 2 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

257 (d) Any GPP NPE Crosstalk<br />

Test (#9)<br />

513 (e) Any Digital Port Sanity<br />

<strong>test</strong> (#565)<br />

769 (f) Any Digital Port<br />

Looparound Test<br />

(#13)<br />

3840 (g) Any Hook State Inquiry<br />

<strong>test</strong> (#566)<br />

On/Off<br />

Board<br />

Recommended Action<br />

MIN ON <strong>test</strong> port location l r 3<br />

MIN ON <strong>test</strong> port location r 2<br />

MIN ON <strong>test</strong> port location r 3<br />

Notes:<br />

a. Error Type 0: run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each <strong>test</strong>’s description, <strong>and</strong> follow its procedures.<br />

b. Error Type 1: there was a hardware failure on a digital port’s circuitry. Replace the<br />

Maintenance/Test circuit pack if the alarm is not resolved by the comm<strong>and</strong> above.<br />

c. Error Type 18: the port was busied out by busyout port location. Release the port<br />

using release port location.<br />

d. Error Type 257: the Maintenance/Test digital port is talking on more than just its assigned<br />

time slot. Replace the Maintenance/Test circuit pack.<br />

e. Error Type 513: the Maintenance/Test digital port has failed its self-<strong>test</strong>. Because the Digital<br />

Port Sanity <strong>test</strong> runs only on port 2, but <strong>test</strong>s both ports 2 <strong>and</strong> 3, both ports are alarmed<br />

when the <strong>test</strong> fails. The comm<strong>and</strong> indicates to <strong>test</strong> port 2, even if the <strong>error</strong> is logged against<br />

port 3.<br />

f. Error Type 769: the Maintenance/Test digital port was unable to successfully loop data from<br />

a tone generator to a tone detector.<br />

g. Error Type 3840: call processing records do not agree with on-board records for the hook<br />

state (on-/off-hook) of the Maintenance/Test digital port. This <strong>error</strong> is not service-affecting<br />

<strong>and</strong> no action is required.<br />

682 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />