Figure 28: Center Stage Switch Configuration with Duplicated PNC<br />

FIBER<br />

FIBER<br />

SN #1 E S S S S<br />

SN #2 S S S<br />

CAB 1 I N N N N<br />

CAB 2 N N N<br />

CARRIER D I C I I CARRIER D I<br />

C I<br />

METALLIC<br />

CABLE<br />

1 2 10 13 20 21 Slot #<br />

1 2<br />

10<br />

13<br />

METALLIC<br />

CABLE<br />

FIBER<br />

EPN EPN<br />

E<br />

E<br />

CAB 2<br />

I CAB 3<br />

CARRIER B I<br />

CARRIER B<br />

E<br />

I<br />

E<br />

CAB 2<br />

CAB 3<br />

CARRIER A I CARRIER A<br />

Slot #<br />

1 1<br />

A-PNC<br />

In a duplicated center stage switch configuration, two EIs are needed in each PN. One resides<br />

in the PNC’s A side <strong>and</strong> one in the B side. Note that a PNC designation (A or B) does not<br />

directly designate the carrier where an EI resides. The active PNC’s EI is the one acting as the<br />

PN’s Archangel (TDM bus master). This EI’s amber LED should be blinking at a rate of<br />

2 seconds on <strong>and</strong> 200 ms off. Whereas, the amber LED on st<strong>and</strong>by PNC’s EI should be off.<br />

A PN (<strong>and</strong> thus, the EIs contained within it) can be remoted via a DS1 Converter complex. This<br />

requires that a fiber link (providing connectivity to the remoted PN) be administered with an<br />

associated DS1 Converter complex. This complex consists of two TN574 DS1 Converter<br />

(DS1C-BD) circuit packs connected by from 1 to 4 DS1 facilities. Figure 29: Fiber Link with<br />

DS1 Converter Complex shows where the DS1 converter complex fits into an EI-to-SNI or<br />

EI-to-EI fiber link. For more information, see DS1C-BD (DS1 Converter Circuit Pack).<br />

430 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

2<br />

FIBER<br />

B-PNC<br />

FIBER<br />

SN #1 E S S S S<br />

SN #2 S S S<br />

CAB 1 I N N N N<br />

CAB 2 N N N<br />

CARRIER E I C I I CARRIER E I<br />

C I<br />

Slot #<br />

Slot #<br />

1 2 10 13 20 21<br />

1 2 10 12 13<br />

FIBER<br />