Communication Manager Maintenance Object Repair Procedures<br />

Table 55: Error type 1281 Aux Data <strong>and</strong> repair procedures 3 of 3<br />

Aux<br />

Data<br />

Alarm<br />

Description<br />

23 High-level path<br />

Remote defect<br />

Indicator:<br />

HP_RDI<br />

24 Loss of cell<br />

delineation<br />

(LCD)<br />

27 SIGCON_DO<br />

WN ATM<br />

switch high<br />

level signal.<br />

Repair procedure<br />

The far end is detecting a major problem with the signal that this<br />

board is transmitting. The transmitted payload is invalid.<br />

1. Make sure the ATM switch port (or a MUX port, if present<br />

between ATM switch <strong>and</strong> the ATM-TRK board) is the same as the<br />

ATM-TRK circuit pack’s cable interface.<br />

2. Run <strong>test</strong> board location.<br />

If Test #1259 fails with Error Code 23, connect a fiber<br />

back-to-back in a looped mode (one str<strong>and</strong> of fiber connecting<br />

the transmit transceiver to the receive transceiver of the<br />

board) <strong>and</strong> see if the amber LED flash goes away.<br />

● If it does the problem is off-board.<br />

● If the amber LED continues to flash, replace the circuit<br />

pack.<br />

On board ATM framer chip is not able to frame cells based on the<br />

cell header.<br />

1. Reset the board with reset board location.<br />

2. If the <strong>error</strong> persists, replace the board.<br />

The board cot communicate with the ATM switch.<br />

1. Busyout the board (busyout board location).<br />

2. Test the board (<strong>test</strong> board long location).<br />

3. If Test #1260 fails, replace the board.<br />

4. If Test #1260 passes, make sure the ATM address on both the<br />

server <strong>and</strong> the ATM switch sides are the same for this board.<br />

5. If the address is the same, change the port on the ATM switch<br />

side.<br />

6. If the <strong>error</strong> is resolved, the problem is on the ATM switch port.<br />

j. Error Type 1537: LANHO bus timeout. The circuit pack is transmitting too many bytes on<br />

the LAN bus for a single frame. This can be due to:<br />

● an on-board fault.<br />

● a faulty data received on one of the circuit pack’s external ports.<br />

If the <strong>error</strong> occurs three times in 10 minutes, the board is isolated from the packet bus, <strong>and</strong><br />

the board is alarmed. To clear the alarm:<br />

1. Restore this circuit pack to the packet bus with this comm<strong>and</strong> sequence:<br />

a. busyout board location<br />

b. reset board location<br />

c. <strong>test</strong> board location long<br />

192 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

3 of 3