Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

For IPMEDPRO: Use the change ip-interface screen to disable the Media Processor’s IP<br />

interface before performing this procedure.<br />

For the Tone-Clock circuit packs, DS1 Interface circuit packs, <strong>and</strong> DS1 Interface Media<br />

Modules, this <strong>test</strong> is executed as part of the long <strong>test</strong> sequence.<br />

This <strong>test</strong> is run on the following maintenance objects:<br />

● DS1-BD (DS1 Interface Circuit Pack)<br />

● MAPD-BD (MAPD Interface Circuit Pack)<br />

● MEDPRO (Media Processor MAPD Circuit Pack)<br />

● MG-ANA (Analog Media Module)<br />

● MG-DS1 (DS1 Interface Media Module)<br />

● MMI-BD (Multimedia Interface Circuit Pack)<br />

● RC-BD (Radio Controller Board)<br />

● TDM-CLK (TDM Bus Clock)<br />

● TONE-BD (Tone-Clock Circuit Pack)<br />

● TONE-PT (Tone Generator)<br />

● UDS1-BD (UDS1 Interface Circuit Pack)<br />

● XXX-BD (Common Port Circuit Pack/Media Module)<br />

Table 305: SAKI Sanity Test (#53) 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT System resources required for this <strong>test</strong> are not available.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1160 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />