Notes:<br />

a. Error Type 0: run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each appropriate <strong>test</strong>’s description, <strong>and</strong> follow its recommended<br />

procedures.<br />

b. Error Type 18: this port has been busied out by busyout port location.<br />

c. Error Type 257: the NPE Crosstalk <strong>test</strong> (#6) failed.<br />

d. Error Type 513: the VC DSP Port Local TDM Loopback Test (#1104) failed. Run the long<br />

<strong>test</strong> sequence.<br />

e. Error Type 778 - 781: a critical hardware failure has been detected on the circuit pack.<br />

Reset the port by busyout port location <strong>and</strong> reset port location. If the VC<br />

Reset DSP <strong>test</strong> (#1106) passes, then the on-board circuitry is healthy. Retire the alarm with<br />

<strong>test</strong> port location long clear.<br />

f. Error Type 1025: the VC DSP port reported loss of framing on the Service Chel between<br />

the VC <strong>and</strong> MMI circuit packs.<br />

g. Error Type 1281: the VC DSP Port DSP Looparound Test (#1105) failed.<br />

h. Error Type 3840: the DSP corresponding to this port on the VC circuit pack reported a<br />

firmware <strong>error</strong>. No action is required.<br />

<strong>Dem<strong>and</strong></strong> <strong>test</strong> <strong>descriptions</strong> <strong>and</strong> <strong>error</strong> <strong>codes</strong><br />

Investigate <strong>test</strong>s in the order presented. By clearing <strong>error</strong>s associated with the first <strong>test</strong>, <strong>error</strong>s<br />

generated from other <strong>test</strong>s may also be cleared. Click on the link to see the full description of<br />

the <strong>test</strong>, <strong>error</strong> <strong>codes</strong>, <strong>and</strong> recommended actions.<br />

Order of Investigation Short Test<br />

Sequence<br />

Long Test<br />

Sequence<br />

1056 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

Restart<br />

Sequence<br />

VC DSP Port NPE Crosstalk Test (#1103) X D<br />

VC DSP Port Local TDM Loopback Test (#1104) X X D<br />

VC DSP Port DSP Looparound Test (#1105) X X D<br />

VC Port Reset DSP Test (#1106)<br />

1. D = Destructive; ND = Nondestructive<br />

X D<br />