RSCL-PT (Remote Socket Control Link)<br />

MO Name in Log Alarm Level Initial Comm<strong>and</strong> to Run Full Name of MO<br />

RSCL-PT WRN Remote socket control<br />

link<br />

The Remote Socket Control Link is the control message link between the switch software <strong>and</strong><br />

firmware on the TN799DP C-LAN or TN2501AP VAL circuit packs.<br />

Error log entries <strong>and</strong> recommended actions<br />

Table 227: RSCL-PT Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

Notes:<br />

a. Error Type 130: The associated circuit pack has been removed or has been insane for > 11<br />

minutes. To clear this <strong>error</strong>, make sure that the circuit pack is installed. If the circuit pack is<br />

installed, pull <strong>and</strong> re-insert the circuit pack to reset it.<br />

<strong>Dem<strong>and</strong></strong> <strong>test</strong> <strong>descriptions</strong> <strong>and</strong> <strong>error</strong> <strong>codes</strong><br />

There are no dem<strong>and</strong> <strong>test</strong>s associated with RSCL-PT.<br />

On/Off<br />

Board<br />

130 (a) WRN ON<br />

816 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

Recommended<br />

Action