Expansion Interface Lock Query Test (#304)<br />

Expansion Interface Lock Query Test (#304)<br />

The Expansion Interface Lock Query Test queries the ATM EI circuit pack for its status<br />

concerning a lock to the backplane system clock. The <strong>test</strong> passes if the response is "in lock".<br />

The <strong>test</strong> fails if the response is "out of lock". This <strong>test</strong> runs on ATM-EI (Expansion Interface<br />

Circuit Pack).<br />

Table 388: Expansion Interface Lock Query Test (#304) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2000 ABORT Response from the <strong>test</strong> was not received within the time allowed.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2100 ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2500 ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

FAIL A PN’s unduplicated ATM-EI circuit pack responded incorrectly, or a PN’s<br />

active ATM-EI circuit pack could not communicate with the PN’s circuit<br />

packs.<br />

1. If the PN’s active ATM-EI circuit pack is failing <strong>and</strong> duplicated PNC<br />

is enabled:<br />

a. Enter reset PNC interchange to switch to the st<strong>and</strong>by<br />

PNC.<br />

b. Repeat the short <strong>test</strong> sequence.<br />

c. If <strong>test</strong> continues to fail, enter reset board location to reset<br />

the ATM-EI circuit pack.<br />

2. If the PN’s unduplicated ATM-EI circuit pack is failing:<br />

a. Enter display <strong>error</strong>s <strong>and</strong> display alarms, <strong>and</strong> follow the<br />

associated repair procedures for TDM-CLK, TONE-BD, or<br />

SYNC alarms/<strong>error</strong>s.<br />

b. Repeat the short <strong>test</strong> sequence.<br />

c. If <strong>test</strong> continues to fail, replace the circuit pack or transceiver.<br />

PASS Communication to the ATM-EI circuit pack is functioning correctly.<br />