Error log entries <strong>and</strong> recommended actions<br />

Table 177: MEDPROPT Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

MEDPROPT (MEDPRO DSP PORT)<br />

Recommended Action<br />

0 (a) 0 Any Any Any <strong>test</strong> board location<br />

1 (b) Any DSP Capacity <strong>test</strong><br />

(#1382)<br />

18 (c) 0 busyout port<br />

location<br />

258 (d) Any DSP Capacity <strong>test</strong><br />

(#1382)<br />

513 (e) DSP Capacity <strong>test</strong><br />

(#1382)<br />

515 (f) Any DSP Capacity Query<br />

<strong>test</strong> (#1382)<br />

769 Any TDM NIC<br />

Looparound <strong>test</strong><br />

(#1380)<br />

770 (g)<br />

1025 (h) Any<br />

ON <strong>test</strong> board location l r 5<br />

WRN OFF release port location<br />

WRN ON <strong>test</strong> board location l r 5<br />

MIN ON <strong>test</strong> port location<br />

MIN ON <strong>test</strong> board location l r 5<br />

MIN ON <strong>test</strong> port location l r 10<br />

Notes:<br />

a. Error Type 0: Run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each <strong>test</strong>’s description <strong>and</strong> follow its procedures.<br />

b. Error Type 1: For the TN802B only, less than three DSPs are OOS (out of service), <strong>and</strong> no<br />

alarm is raised. The Aux Data field contains the number of DSPs that are OOS.<br />

c. Error Type 18: the MEDPRO has been busied out by busyout port location.<br />

1. Release the port (release port location).<br />

d. Error Type 258: For the TN802B only, more than three, but less than 9 DSPs are OOS (out<br />

of service), <strong>and</strong> a WARNING alarm is raised. The Aux Data field contains the number of<br />

DSPs that are OOS.<br />

e. Error Type 513: For the TN2302 <strong>and</strong> TN2602 only, the port is OOS (out of service) because<br />

an associated DSP is bad.<br />