This <strong>test</strong> runs on DIG-LINE (Digital Line).<br />

Digital Terminal Remote Looparound Test (#1201)<br />

Table 481: Digital Terminal Remote Looparound Test (#1201) 1 of 3<br />

Error<br />

Code<br />

1000<br />

1001<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

ABORT System resources required to run this <strong>test</strong> are not available.<br />

The port may be busy with a valid call.<br />

1. Enter display port location to determine the station<br />

extension or attendant number of the port.<br />

2. Enter status station or status attendant to determine the<br />

service state of the port. If the port is in use, wait until it is idle<br />

before <strong>test</strong>ing. Attendants are always in use (off-hook) if the<br />

h<strong>and</strong>set is plugged in <strong>and</strong> the port is not busied out.<br />

3. If the port status is idle, then retry the comm<strong>and</strong> at 1-minute<br />

intervals up to 5 times.<br />

1001 ABORT System resources required to run this <strong>test</strong> are not available.<br />

1. If the port status is idle, then retry the comm<strong>and</strong> at 1-minute<br />

intervals up to 5 times.<br />

1002 ABORT The system could not allocate time slots for the <strong>test</strong>. The system may be<br />

under heavy traffic conditions, or it may have time slots out-of-service<br />

due to TDM-BUS <strong>error</strong>s. A system is considered under heavy traffic<br />

when the Call Processing Occupancy is greater than 50% or when the<br />

System Management <strong>and</strong> the Call Processing Occupancies together<br />

exceed 65%.<br />

1. Enter status health to view the occupancy measurements.<br />

2. Resolve any TDM-BUS (TDM Bus) <strong>error</strong>s.<br />

3. If the system has no TDM-BUS <strong>error</strong>s <strong>and</strong> is not h<strong>and</strong>ling heavy<br />

traffic, retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />