ETR-PT (Enhanced Tone Receiver Port)<br />

Note: Replacing<br />

MO Name in<br />

Log<br />

Alarm<br />

Level<br />

ETR-PT MAJ<br />

MIN<br />

WRN<br />

Initial Comm<strong>and</strong> to Run Full Name of MO<br />

Note:<br />

the Tone-Clock circuit pack requires a special procedure which is<br />

described in TONE-BD (Tone-Clock Circuit Pack). That section also describes the<br />

LED display for this board.<br />

TN2312AP IPSI Circuit Pack’s Tone-Clock<br />

<strong>test</strong> port location Enhanced Tone Receiver Port<br />

For a PN with a TN2312 IPSI, the TONE-BD is a module located on the IPSI circuit pack. It<br />

provides tone generation, tone detection, call classification, <strong>and</strong> clock generation <strong>and</strong><br />

synchronization. The TN2312 replaces the TN2182B Tone-Clock board <strong>and</strong> is inserted into<br />

each PN’s Tone-Clock slot. For a non IPSI PN, the TN2182B Tone-Clock circuit packs provide<br />

the TONE-BD functions.<br />

The TN2312 IPSI circuit pack (for PNs equipped with IPSIs) or the Tone-Clock circuit packs (for<br />

non IPSI PNs) both house two independent components:<br />

● Tone Generator that provides every tone needed by the system<br />

● Clock that generates clocks for both the system’s Time Division Multiplex (TDM) bus <strong>and</strong><br />

the LAN bus. It also aids in monitoring <strong>and</strong> selecting internal synchronization references.<br />

When resolving <strong>error</strong>s/alarms on an IPSI or Tone-Clock circuit pack, the following sections<br />

should also be consulted:<br />

● For a non IPSI PN, use set tone-clock UC to establish the tone <strong>and</strong> synchronization<br />

resources for the system.<br />

● For an IPSI PN, use set ipserver-interface UC to establish the tone <strong>and</strong><br />

synchronization resources for the system.<br />

● TONE-PT (Tone Generator)<br />

● TDM-CLK (TDM Bus Clock)<br />

● SYNC (Synchronization)<br />

● TONE-BD<br />

● PKT-INT (IPSI only)<br />

422 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers