19.12.2012 Views

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Table 413: BRI Port Local LAN Looparound Test (#618) 2 of 2<br />

Error<br />

Code<br />

2012<br />

2100<br />

Test<br />

Result<br />

BRI Port Local TDM Looparound Test (#619)<br />

BRI Port Local TDM Looparound Test (#619)<br />

ABORT Internal system <strong>error</strong><br />

Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

FAIL The looparound <strong>test</strong> has failed.<br />

1. If the <strong>test</strong> fails repeatedly, attempt to reset the circuit pack if the<br />

other ports on the board are idle.<br />

2. Rerun the <strong>test</strong>. If the <strong>test</strong> fails again, enter <strong>test</strong> pkt pn#. If this<br />

fails, follow the failure procedures in PKT-BUS (Packet Bus).<br />

3. If the <strong>test</strong>s executed in step 2 pass, the problem is local to the BRI<br />

board. Replace the circuit pack.<br />

PASS The BRI Port Local LAN Looparound <strong>test</strong> has passed.<br />

1. Enter release board location to put the board <strong>and</strong> ports back<br />

into service.<br />

This <strong>test</strong> is destructive.<br />

This <strong>test</strong> verifies the connectivity of a BRI port across the TDM Bus. It aborts if calls associated<br />

with the port are in progress. Failure of this <strong>test</strong> indicates an on-board fault associated with the<br />

port hardware on the circuit pack.<br />

This looparound <strong>test</strong> runs the following individual <strong>test</strong>s on the two B-Chels (B1 <strong>and</strong> B2)<br />

associated with the port:<br />

● Looparound <strong>test</strong> across the TDM Bus for B1.<br />

● Conference Circuit <strong>test</strong> for B1.<br />

Description / Recommendation<br />

● Looparound <strong>test</strong> across the TDM Bus for B2.<br />

2 of 2<br />

● Conference Circuit <strong>test</strong> for B2.<br />

The <strong>test</strong>s are run in the above order. If one <strong>test</strong> fails, the remaining <strong>test</strong>s in the sequence are not<br />

executed <strong>and</strong> an <strong>error</strong> code is returned at that point.<br />

This <strong>test</strong> runs on BRI-PORT (ISDN-BRI Port) <strong>and</strong> TBRI-PT (ISDN Trunk-Side BRI Port).<br />

Issue 5 May 2009 1399