Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 513: RC Hardware Translation Audit (#1317) 3 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

6 FAIL RC has incorrect modem operating parameters.<br />

1. Enter display radio-controller loc to check the<br />

administration. If administered translations are wrong, use<br />

change carrier-frequencies <strong>and</strong>/or change system<br />

parameters wireless to modify as needed.<br />

2. Re-initialize the RC board using the busy, reset, <strong>and</strong> release<br />

comm<strong>and</strong>s.<br />

ANY NO<br />

BOARD<br />

Description / Recommendation<br />

UTAM disablement of radio transmission usually causes this problem.<br />

1. Check the Radio Transmission option. This option can be<br />

changed only at the INADS or higher level.<br />

2. Verify the system is not booting.<br />

3. Enter display radio-controller loc <strong>and</strong> verify that the<br />

RC is administered.<br />

4. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

5. If the <strong>test</strong> continues to abort, escalate the problem.<br />

PASS The RC is functioning normally.<br />

1642 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />