Table 440: SNI-BD Configuration Audit (#759) 3 of 6<br />

Error<br />

Code<br />

102 -<br />

109,<br />

113-<br />

120<br />

Test<br />

Result<br />

Description / Recommendation<br />

Configuration Audit (#759)<br />

FAIL The SNI circuit pack cot communicate with the SNI in a different slot.<br />

1. Determine the slot number of the other SNI: Subtract 100 from the<br />

Error Code. For example, if the Error Code is 107, the SNI slot<br />

number is 7. This number is referred to as the "specified SNI slot".<br />

2. Perform the Fiber link fault isolation procedure in Maintenance<br />

Procedures for <strong>Avaya</strong> Aura Communication Manager, Media<br />

Gateways <strong>and</strong> Servers (03-300432). This will resolve multiple<br />

SNI-PEER <strong>error</strong>s.<br />

3. See Table 435: SNI Slot / Error Type to determine the Error Type for<br />

SNI-PEER <strong>error</strong>s. For example, if the specified SNI slot is 9, the<br />

Error Type is 1793. If the SNI being <strong>test</strong>ed has SNI-PEER <strong>error</strong>s of<br />

the specified Error Type, replace the SNI being <strong>test</strong>ed. Replacing an<br />

SNI may be service interrupting. See SNI-BD (SNI Circuit Pack) for<br />

the procedure for replacing an SNI. To view SNI-PEER <strong>error</strong>s, enter<br />

display <strong>error</strong>s with category PNC-PEER. Retry the comm<strong>and</strong>.<br />

4. If the SNI being <strong>test</strong>ed has SNI-PEER <strong>error</strong>s of the specified Error<br />

Type, replace the SNI in the specified SNI slot. Retry the comm<strong>and</strong>.<br />

112 FAIL The SNI circuit pack cot communicate with the active SNC.<br />

1. Check the <strong>error</strong> log for other SNI circuit packs in the same carrier<br />

with a 257 SNI-BD <strong>error</strong>. Enter display <strong>error</strong>s with category<br />

PNC to view SNI-BD <strong>error</strong>s. If other SNI circuit packs in the same<br />

switch node carrier have <strong>error</strong> 257, then replace the active SNC in<br />

this switch node carrier. Replacing an SNC may be service<br />

interrupting. See SNC-BD (Switch Node Clock Circuit Pack) for the<br />

procedure for replacing an SNC. If other SNI circuit packs in the<br />

same carrier do not have SNI-BD Error Type 257 logged, proceed to<br />

step 2.<br />

2. Replace this SNI. Replacing an SNI may be service interrupting. See<br />

SNI-BD (SNI Circuit Pack) for the procedure for replacing an SNI.<br />

3. Replace the active SNC in the same switch node carrier. Replacing<br />

an SNC may be service interrupting. See SNC-BD (Switch Node<br />

Clock Circuit Pack) for the procedure for replacing an SNC.<br />

3 of 6<br />

Issue 5 May 2009 1475