Table 392: DS1 CO Trunk Dial Tone Seizure Test (#314) 2 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

DS1 CO Trunk Dial Tone Seizure Test (#314)<br />

1020 ABORT The DS1 Interface circuit pack is out-of-service.<br />

1. Look for DS1-BD <strong>and</strong> UDS1-BD <strong>error</strong>s in the Error Log. If present,<br />

see DS1-BD (DS1 Interface Circuit Pack) or UDS1-BD (UDS1<br />

Interface Circuit Pack) for the repair procedures.<br />

2. Retry the comm<strong>and</strong>.<br />

1040 ABORT This port may be an access endpoint.<br />

1. Verify that this port is an access endpoint with<br />

display port location<br />

2. If the port has been administered as an access endpoint, this is a<br />

normal abort, <strong>and</strong> this <strong>error</strong> can be ignored.<br />

1412 ABORT This <strong>test</strong> does not run on media modules or media gateways. Ignore.<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2012 ABORT The <strong>test</strong> was aborted due to an internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2100 ABORT Could not allocate the necessary system resources for this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2000 FAIL Response to the seizure message was not received within the allowed<br />

time.<br />

1. Enter list configuration board location. If the circuit<br />

pack is a TN767B vintage 8 or 9, a failure of <strong>test</strong> 314 causes a<br />

subsequent failure of <strong>test</strong> 7 due to a firmware bug. Eventually, the<br />

board <strong>and</strong> all of its ports will be taken out of service <strong>and</strong><br />

extraneous on-board alarms will be generated. Replace the circuit<br />

pack with a TN767C V3 or later.<br />

2. Verify that the Trunk Type field on the Trunk Administration form<br />

matches the trunk type administered on far-end switch.<br />

3. Look for DS1-BD <strong>and</strong> UDS1-BD <strong>error</strong>s in the <strong>error</strong> log. If present,<br />

see DS1-BD (DS1 Interface Circuit Pack) or UDS1-BD (UDS1<br />

Interface Circuit Pack).<br />

4. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />