Packet Interface Read <strong>and</strong> Clear Counters (#887)<br />

Table 461: Packet Interface Read <strong>and</strong> Clear Counters Test (#887) 3 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

5. If Error Code 512 or 768 is reported for an active IPSI’s Packet<br />

Interface module, the receive FIFO in the PKT-INT has<br />

overflowed. This may indicate the need for additional IPSI circuit<br />

packs.<br />

For the current hardware configuration, only one IPSI circuit pack<br />

is allowed per PN. Escalate the problem if not corrected by the<br />

following repair steps. Retry the comm<strong>and</strong> after one minute if the<br />

<strong>test</strong> continues to fail.<br />

a. If the Packet Interface module is on the active IPSI<br />

(S8700-series Fiber-PNC: <strong>and</strong> this is a high- or critical-reliability<br />

system), use set ipserver-interface to perform a pled<br />

IPSI interchange. Replace the st<strong>and</strong>by IPSI circuit pack.<br />

b. Otherwise, replace the IPSI circuit pack at a time that would<br />

cause the least service disruption.<br />

6. If Error Code 512 or 768 is reported for a st<strong>and</strong>by IPSI’s Packet<br />

Interface module, replace the st<strong>and</strong>by IPSI circuit pack.<br />