Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 484: CSU Repeater Loopback Test (#1211) 2 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1039 ABORT The DS1 Interface circuit pack is providing timing for the system. Executing<br />

this <strong>test</strong> could cause major system disruption.<br />

If the DS1 Interface circuit pack needs to be <strong>test</strong>ed, set the<br />

synchronization reference to another DS1 Interface circuit pack or to the<br />

Tone-Clock circuit with the following comm<strong>and</strong> sequence:<br />

1. disable synchronization-switch<br />

2. set synchronization location<br />

3. enable synchronization-switch<br />

1412 ABORT This <strong>test</strong> does not run on media modules or media gateways. Ignore.<br />

1950 ABORT Another loopback/span <strong>test</strong> is already executing on the DS1 board or the<br />

board is in a network requested loopback mode (Line loopback or Payload<br />

loopback). The <strong>error</strong> log indicates whether a Customer Loopback Jack<br />

<strong>test</strong>, Far CSU Loopback <strong>test</strong>, or the One-Way Span <strong>test</strong> is executing or if<br />

the board is in line loopback or payload loopback mode. Only one<br />

long-duration loopback/span <strong>test</strong> can be active at a given time.<br />

If a loopback/span <strong>test</strong> is already active, that <strong>test</strong> must be deactivated via<br />

<strong>test</strong> ds1-loop location end-loopback/span-<strong>test</strong> in order to<br />

run this <strong>test</strong>.<br />

1951 ABORT The CSU Repeater Loopback <strong>test</strong> could not be executed because the<br />

120A CSU module/T1 sync splitter was not physically installed. Physically<br />

connect the 120A1 CSU module/T1 sync splitter to the TN767E board on<br />

the back of the port carrier.<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

1. Check for board hyperactivity. See Hyperactive DS1/UDS1 Interface<br />

Circuit Pack/Media Module.<br />

2100 ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

FAIL DS1 Interface circuit pack failed the CSU Repeater Loopback <strong>test</strong>.<br />

1. Retry <strong>test</strong> ds1-loop location ds1/csu-loopback-<strong>test</strong>s.<br />

2. If the RLB <strong>test</strong> continues to fail, <strong>and</strong> the CSU Equipment Loopback<br />

<strong>test</strong> (#1210) passed, replace the CSU module/T1 sync splitter.<br />