SYNC (Port Network Synchronization)<br />

Notes for Sheet 1 through Sheet 5 flowcharts. (When checking for slip <strong>error</strong>s, use the previous<br />

Table 244: Error Log Entries for Slip Errors.<br />

1. Use status synchronization to see if synchronization is enabled, <strong>and</strong> to determine<br />

the on-line reference. If the on-line reference is a Tone-Clock board, the switch is operating<br />

in free run mode.<br />

If Stratum 3 is displayed, <strong>and</strong> no DS1s are connected to the Stratum-3 clock or no DS1<br />

connection existed to the Stratum-3 clock for over 24 hours, then the Stratum-3 clock is in<br />

free run mode.<br />

2. Check for slip <strong>error</strong>s against DS1-BD <strong>and</strong> UDS1-BD. In the <strong>error</strong> log (display <strong>error</strong>s)<br />

look for the following Error Types to identify slips against these board types.<br />

Board Type Error log name Log Entry (for slips)<br />

DS1 Interface DS1-BD 3073 - 3160<br />

UDS1 Interface UDS1-BD 3073 - 3160<br />

For slips on either of these board types, first refer to the individual board’s section in this<br />

manual. Follow the <strong>test</strong> <strong>and</strong> repair steps in those sections.<br />

3. If Stratum 3 is administered (display synchronization) <strong>and</strong> on-line (status<br />

synchronization), check for DS1-BD or UDS1-BD slip <strong>error</strong>s for the DS1(s) or<br />

UDS1(s) used as input to the Stratum-3 clock. Check the LED indications on the Stratum-3<br />

clock to determine which DS1 is providing input to Stratum 3, <strong>and</strong> examine the<br />

cross-connect information for that DS1.<br />

4. Check for slips <strong>error</strong>s against EXP-INTF, SNI-BD, <strong>and</strong> TDM-CLK. In the <strong>error</strong> (display<br />

<strong>error</strong>s) log, look for the following Error Types to identify slips against these board types.<br />

Board Type Error log name Log Entry (for slips)<br />

Expansion Interface EXP-INTF 2305<br />

Switch Node Interface SNI-BD 1537<br />

Tone Clock TDM-CLK 1025<br />

DS1 Converter DS1C-BD 3329<br />

5. Check status synchronization for the current DS1 reference. If a DS1 or UDS1 is<br />

the on-line reference, check for slips on that DS1 or UDS1.<br />