Investigate any alarms against SN-CONF, SNI-BD, FIBER-LK. The last two digits of the<br />

Error Code indicate the fiber-link number of the fiber that reported the retired alarm. Use<br />

list fiber-link to show the location of the fiber.<br />

q. Error Type 20000 – 20063: a spontaneous PNC interchange took place in response to the<br />

retiring of an alarm on the B-PNC associated with fault class FC_EAL. Use status pnc to<br />

look at the state of health indexes for the PNCs, <strong>and</strong> investigate any associated alarms.<br />

Adding 1 to the last two digits of the Error Code gives the PN number of the port network<br />

that reported the retired alarm. (20003 points to port network 4.) Use list config<br />

port-network to show the cabinet number associated with a port network.<br />

r. Error Type 20100 – 20163: a spontaneous PNC interchange took place in response to the<br />

retiring of an alarm on the B-PNC associated with fault class FC_INL. Use status pnc to<br />

look at the state of health indexes for the PNCs, <strong>and</strong> investigate any associated alarms.<br />

Adding 1 to the last two digits of the Error Code gives the PN number of the port network<br />

that reported the retired alarm. (20103 points to port network 4.) Use list config<br />

port-network to show the cabinet number associated with a port network.<br />

s. Error Type 20200 – 20263: a spontaneous PNC interchange took place in response to the<br />

retiring of an alarm on the B-PNC associated with fault class FC_HW. Use status pnc to<br />

look at the state of health indexes for the PNCs, <strong>and</strong> investigate any associated alarms.<br />

Adding 1 to the last two digits of the Error Code gives the PN number of the port network<br />

that reported the retired alarm. (20203 points to port network 4.) Use list config<br />

port-network to show the cabinet number associated with a port network.<br />

t. Error Type 20300 – 20363: a spontaneous PNC interchange took place in response to the<br />

retiring of an alarm on the B-PNC associated with fault class FC_PER. Use status pnc to<br />

look at the state of health indexes for the PNCs, <strong>and</strong> investigate any associated alarms.<br />

Adding 1 to the last two digits of the Error Code gives the PN number of the port network<br />

that reported the retired alarm. (20303 points to port network 4.) Use list config<br />

port-network to show the cabinet number associated with a port network.<br />

u. Error Type 20400 – 20463: a spontaneous PNC interchange took place in response to the<br />

retiring of an alarm on the B-PNC associated with fault class FC_DS1. Use status pnc to<br />

look at the state of health indexes for the PNCs, <strong>and</strong> investigate any associated alarms.<br />

Adding 1 to the last two digits of the Error Code gives the PN number of the port network<br />

that reported the retired alarm. (20403 points to port network 4.) Use list config<br />

port-network to show the cabinet number associated with a port network.<br />

v. Error Type 20500 – 20563: a spontaneous PNC interchange took place in response to the<br />

retiring of an alarm on the B-PNC associated with fault class FC_BFD. Use status pnc to<br />

look at the state of health indexes for the PNCs, <strong>and</strong> investigate any associated alarms.<br />

Adding 1 to the last two digits of the Error Code gives the PN number of the port network<br />

that reported the retired alarm. (20203 points to port network 4.) Use list config<br />

port-network to show the cabinet number associated with a port network.<br />

w. Error Type 20600 – 20664: a spontaneous PNC interchange took place in response to the<br />

retiring of an alarm on the B-PNC associated with fault class FC_SNIL. Use status pnc to<br />

look at the state of health indexes for the PNCs, <strong>and</strong> investigate any associated alarms. The<br />

last two digits of the Error Code indicate the fiber-link number (01-27) of the fiber that<br />

reported the retired alarm. Use list fiber-link to show the location of the fiber.<br />