Table 34: ATM-EI Error Log Entries 3 of 3<br />

Error<br />

Type<br />

ATM-EI (Expansion Interface Circuit Pack)<br />

2818 (s) Any MIN ON <strong>test</strong> board location<br />

3329 (t) 3 LANHO critical <strong>error</strong> MAJ OFF<br />

3585 (u) ATM Framer<br />

Looparound (#1260)<br />

3586 (u) ATM Framer<br />

Looparound (#1260)<br />

3841 (v)<br />

3842(w)<br />

3843 (x)<br />

Aux<br />

Data<br />

3999 (y) Any<br />

Any (z) 32767<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

MAJ ON <strong>test</strong> board location l<br />

MAJ ON <strong>test</strong> board location l<br />

3 of 3<br />

Notes:<br />

a. Error Type 0: Run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each appropriate <strong>test</strong>’s description, <strong>and</strong> follow its recommended<br />

procedures.<br />

b. Error Type 2: The on-board DUART chip failed. This results in communication failure<br />

between the PN’s Maintenance board <strong>and</strong> the ATM-EI board. The Maintenance board<br />

should have a red LED lit because the link to the ATM-EI is down in this PN.<br />

1. Reset the board with reset board location.<br />

2. If the board does not recover, replace the board.<br />

c. Error Type 18: The ATM-EI circuit pack has been busied out.<br />

1. Release the circuit pack (release board location).<br />

d. Error Type 23: An ATM-EI circuit pack has been administered with the add atm pnc n<br />

comm<strong>and</strong>, but the circuit pack has not been physically inserted into the system.<br />

1. Insert an ATM-EI circuit pack at this location.<br />

e. Error Type 125: A wrong circuit pack is located in the slot where the ATM-EI circuit pack is<br />

logically administered.<br />

1. Either remove the wrong circuit pack <strong>and</strong> insert the ATM-EI circuit pack or remove the<br />

ATM-EI administration. See Basic ATM PNC Administration.<br />