Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 328: Ring Generator Query Test (#118) 3 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

FAIL<br />

(cont’d)<br />

Description / Recommendation<br />

4. The ring generator is defective.<br />

a. If the reset button on the ring generator is out, push it in.<br />

b. Originate calls to several analog stations on different port circuit<br />

packs in different carriers in the affected port network.<br />

c. If no stations ring, replace the ring generator. Otherwise, If<br />

called stations ring, the fault is cleared. Rerun the <strong>test</strong>.<br />

d. If the <strong>test</strong> still fails, the active Tone-Clock may be faulty <strong>and</strong><br />

incorrectly reporting the level of the ringing voltage. Replace<br />

the active Tone-Clock, <strong>and</strong> rerun the <strong>test</strong>. See TONE-BD<br />

(Tone-Clock Circuit Pack) for details on replacing the<br />

Tone-Clock. Rerun the <strong>test</strong>.<br />

1212 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />