Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 392: DS1 CO Trunk Dial Tone Seizure Test (#314) 3 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

2053 FAIL At least one of the following <strong>error</strong>s was found on the DS1 circuit pack:<br />

● 1281 - Loss of signal<br />

● 1793 - Blue alarm<br />

● 2049 - Red alarm<br />

● 2305 - Yellow alarm<br />

● 1537 - Hyperactivity<br />

Look for these Error Types in the Error Log, then follow the procedures<br />

described in DS1-BD (DS1 Interface Circuit Pack) or UDS1-BD (UDS1<br />

Interface Circuit Pack) that is appropriate for the Error Type that was<br />

found.<br />

FAIL The trunk cot be seized for an outgoing call. This could cause inline<br />

failures to be reported against the trunk (no answer would report Error<br />

Type 257 with auxiliary data 57487 in the <strong>error</strong> log).<br />

1. Verify the Trunk Type field on the trunk administration screen<br />

screen matches the trunk type administered on far-end switch.<br />

2. Look for DS1-BD or UDS1-BD <strong>error</strong>s in the Error Log. If <strong>error</strong>s<br />

exist, see DS1-BD (DS1 Interface Circuit Pack) or UDS1-BD<br />

(UDS1 Interface Circuit Pack).<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

PASS The trunk can be seized for an outgoing call.<br />

See NO BOARD for the repair procedures.<br />

Expansion Interface Control Chel Test (#316)<br />

If an ATM-EI or EI circuit pack is an active ATM-EI or EI in the PN (amber LED on long/off short),<br />

the Expansion Interface Control Chel <strong>test</strong> checks to see if the ATM-EI or EI circuit pack can<br />

communicate with other circuit packs in the PN using the PN’s TDM bus.<br />