Table 268: TONE-BD Error Log Entries 2 of 2<br />

Error<br />

Type<br />

23 (d) 0 WRN OFF<br />

125 (e) MIN ON<br />

126 (f) MIN ON<br />

257 (g) Any<br />

65535<br />

513 (h) Any<br />

769 (i) 4358<br />

None<br />

Control Chel<br />

Looparound Test<br />

(#52)<br />

TONE-BD (Tone-Clock Circuit Pack)<br />

MIN ON <strong>test</strong> tone-clock<br />

location r 20<br />

1025 (j) 4363 NPE Audit <strong>test</strong> (50) <strong>test</strong> tone-clock<br />

location<br />

1538 (k) Any MIN ON<br />

2049 (l) 0 Clock Health Inquiry<br />

(#46)<br />

2305 (l) 0 Clock Health Inquiry<br />

(#46)<br />

2561 (m) Any MAJ ON<br />

MAJ ON set tone-clock<br />

location override 1<br />

MAJ ON set tone-clock<br />

location override 1<br />

3329 (n) 0 MIN OFF set tone-clock<br />

WRN2 location override1 3840 (o) Any<br />

3848 (p) 0 Clock Health Inquiry<br />

(#46)<br />

set tone-clock<br />

location override 1<br />

3856 (q) MAJ ON set tone-clock<br />

location override 1<br />

3857<br />

3858 (r)<br />

Aux<br />

Data<br />

MAJ ON busyout/release<br />

ipserver-interface<br />

3872 (s) 0 set tone-clock<br />

location override 1<br />

3999 (t) Any<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

1. For a TN2312 IPSI supported port network, use the comm<strong>and</strong> set ipserver-interface.<br />

2. Minor alarms on this MO may be downgraded to Warning based on the value in set options.<br />