ERR-LOG (Error Log)<br />

MO Name in Log Alarm Level Initial Comm<strong>and</strong> to Run Full Name of MO<br />

ERR-LOG none none Error Log<br />

The ERR-LOG MO is responsible for the sanity of the Alarm Log, the Hardware Error Log, <strong>and</strong><br />

the Software Error Log. If an inconsistency is detected in any one of these logs, every log will be<br />

re-initialized <strong>and</strong> a hardware <strong>error</strong> will be logged against ERR-LOG indicating the time of<br />

inconsistency. There are no <strong>test</strong>s <strong>and</strong> no alarms for the Error Log MO. It exists solely for the<br />

purpose of allowing <strong>error</strong>s to be logged against it.<br />

Error Log Entries<br />

Error<br />

Type<br />

Aux Data Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

510 (a) See Note none none none<br />

Notes:<br />

a. Error Type 510: An inconsistency was detected in either the Alarm Log, the Hardware Error<br />

Log, or the Software Error Log. The system attempts to recover the logs but, depending on<br />

the extent of the corruption, some or all entries in the logs may be lost. Any alarms that were<br />

active at the time of this <strong>error</strong> have been cleared. There is no associated <strong>test</strong> for this <strong>error</strong>.<br />

The Aux Data value indicates when the inconsistency was found:<br />

0 During a periodic audit of the Error Log<br />

1 After an extended reboot<br />

2 After a reboot<br />

3 After a Reset System 3 (Cold_1)<br />

4 After a Level-3 System Reset (Cold_1)<br />

4 After a Reset System 2 (Cold_2)<br />

8 After a Level-2 System Reset (Cold_2)<br />

16 After a Level-1 System Reset (Warm Start)<br />

100 After an internal software audit<br />

2500 After a single-process (MDM) restart<br />