Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 469: SNI Sanity Timer Test (#964) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

No board was detected by the <strong>test</strong>.<br />

1. Check that board is properly translated <strong>and</strong> inserted.<br />

2. Run the <strong>test</strong> again. If it fails, reset the board. An SNI should be reset<br />

instead of reseating the circuit pack. The reset board comm<strong>and</strong><br />

should almost never be used on an SNI. It may be necessary to use<br />

reset board if the SNI circuit pack gets into a mode where it cot<br />

communicate with software. If an SNI with active <strong>error</strong>s <strong>and</strong> alarms is<br />

reset, the <strong>error</strong>s <strong>and</strong> alarms may take a while to come back, therefore<br />

reset board can mask real problems.<br />

3. Run the <strong>test</strong> again. If it fails, escalate the problem.<br />

System Link Status Test (#985)<br />

This <strong>test</strong> queries the switch for the status of the system link <strong>and</strong> verifies that every switch<br />

component has the same view of the link state. This <strong>test</strong> runs on SYS-LINK (System Links)<br />

Table 470: System Link Status Test (#985)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1007 ABORT Could not locate the system link associated with this location<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2500 ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

6 FAIL The system link is down.<br />

1. Follow the procedure for Error Type 13 for SYS-LINK (System<br />

Links).<br />

PASS The system link is up.<br />

1548 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />