Error log entries <strong>and</strong> recommended actions<br />

Table 194: M/T-ANL Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 (a) 0 Any Any Any <strong>test</strong> port location<br />

1 (b) 41018 MIN ON <strong>test</strong> port location l r 3<br />

18 0 busyout port<br />

location<br />

257 Any GPP NPE<br />

Crosstalk Test (#9)<br />

513 Any Analog Port Sanity<br />

<strong>test</strong> (#963)<br />

769 Any Analog Port Digital<br />

Looparound (#13)<br />

3840 (c) Any Hook State Inquiry<br />

<strong>test</strong> (#566)<br />

WRN OFF release port location<br />

MIN ON <strong>test</strong> port location l r 3<br />

MIN ON <strong>test</strong> port location r 2<br />

MIN ON <strong>test</strong> port location r 3<br />

Notes:<br />

a. Error Type 0: run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each <strong>test</strong>’s description, <strong>and</strong> follow its procedures. This Error Code<br />

appears in the Error Log only if the MTB circuit pack has been removed since the Error Log<br />

was last cleared. Verify that the circuit pack has been reinserted.<br />

b. Error Type 1: a hardware failure on the Analog Port circuitry. Replace the Maintenance/Test<br />

circuit pack if the comm<strong>and</strong> does not resolve the alarm.<br />

c. Error Type 3840: call processing records did not agree with on-board records for the hook<br />

state (on-/off-hook) of the Maintenance/Test analog port. This <strong>error</strong> is not service-affecting<br />

<strong>and</strong> no action is required.<br />