Table 481: Digital Terminal Remote Looparound Test (#1201) 3 of 3<br />

Error<br />

Code<br />

14<br />

16<br />

Test<br />

Result<br />

Description / Recommendation<br />

FAIL The primary chel is not operating properly.<br />

The secondary chel is not operating properly.<br />

DS1 Board Loopback Test (#1209)<br />

DS1 Board Loopback Test (#1209)<br />

User impact may range from noticing nothing to not being able to use the<br />

port.<br />

1. Check the results of the Local Loop Test (#13).<br />

2. If that <strong>test</strong> fails, suspect the Digital Line circuit pack. Run <strong>test</strong><br />

board location on the Digital Line circuit pack. If the <strong>test</strong>s pass,<br />

replace the terminal.<br />

3. If component replacement does not change the results, then:<br />

a. Run circuit pack <strong>test</strong>s to check the tone generator circuit <strong>and</strong><br />

the Tone Detector circuit using <strong>test</strong> board location.<br />

b. Resolve any problems that are detected on the TONE-PT (Tone<br />

Generator) or TTR-LEV (TTR Level).<br />

PASS The <strong>test</strong> passed. All chels are transmitting properly.<br />

1. To verify that this is not an intermittent problem, repeat this <strong>test</strong> up<br />

to ten times.<br />

2. If problems persist (noisy connections for voice, corrupted data<br />

transfer for data), examine the station, connections, <strong>and</strong> wiring.<br />

3 of 3<br />

This <strong>test</strong> is destructive.<br />

The DS1 BLB (Board Loopback) Test causes a loopback at the DS1 board edge <strong>and</strong> <strong>test</strong>s DS1<br />

board internal circuitry.<br />

This <strong>test</strong> is destructive <strong>and</strong> can only be initiated by entering the comm<strong>and</strong><br />

<strong>test</strong> ds1-loop location ds1/csu-loopback-<strong>test</strong>.<br />

All trunks or ports on the DS1 Interface circuit pack must be busied out using busyout board<br />

before running the BLB <strong>test</strong>.<br />