Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 397: Digital Port Sanity Test (#565) 2 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1019 ABORT An ISDN <strong>test</strong> call is in progress using this Maintenance/Test circuit pack.<br />

The Maintenance/Test circuit pack cot perform a self-<strong>test</strong> on one of its<br />

digital ports while an ISDN <strong>test</strong> call is using either of the digital ports.<br />

1. Enter list isdnpri-<strong>test</strong>call to determine which call is using<br />

the port from the M/T Port column.<br />

2. Wait for the <strong>test</strong> call to complete as indicated in the Start Time <strong>and</strong><br />

Duration fields, or abort the <strong>test</strong> call with clear<br />

isdnpri-<strong>test</strong>call grp#/mem#, where grp#/mem# is<br />

determined from the B-Chel field of list isdnpri-<strong>test</strong>call.<br />

3. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

4. If the <strong>test</strong> continues to abort <strong>and</strong> the port is idle, escalate the problem.<br />

1138 ABORT This <strong>test</strong> does not run on port 3 of the Maintenance/Test circuit pack. This<br />

<strong>test</strong> will only run on port 2. Look at the results of the Digital Port Sanity <strong>test</strong><br />

for port 2.<br />

1. Run the comm<strong>and</strong> again for port 2 using <strong>test</strong> port location<br />

(02) or <strong>test</strong> port location (02) long.<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2100 System resources required to run this <strong>test</strong> are not available.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2500 An internal operation failed; the <strong>test</strong> could not be completed.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

50 FAIL The system was unable to communicate with the port circuitry used for<br />

digital trunk <strong>test</strong>ing.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1366 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />